Power Analyzers: | PA-03090A |
Power Analyzer: PA-03090A |
|
Features:
* Multi-Functions: Watt, VA, W hr, Power factor, ACV, ACA, DCV, DCA, Hz, Ohm
|
* True AC Power (Watt) and apparent power (VA) measurement
|
* True RMS display for ACV, ACA
|
* 0.1 W resolution ( <1000 W ), high precision and high resolution in the low watt range, good performance, for low power LED lamp watt measurement
|
* Super large LCD, easy to read-out, display WATT, power factor, voltage, current values at the same time
|
* Accept different kind current input signal as direct input, inductive clamp probe or CT (current transformer).
|
* Auto range
|
* Built-in peak hold & data hold function
|
* Watt & VA measurement with Hi, low alarm setting capability
|
* RS-232 output interface
|
* Exclusive custom exclusive design LSI circuit, provides high accuracy, reliability and durability
|
* Built-in over input indication
|
* Power supply by DC battery or AC to DC adapter
|
* Built-in low battery indicator
|
* Durable bench type housing plastic case with carrying handle
|
General specifications:
Display
|
93mm x 52 mm LCD display. Multi-display unit, show Volt, Ampere, Watt, Power factor or Hz at same time
|
Measurement
|
WATT, VA, W hr, Power Factor, ACV, ACA, DCV, DCA, Hz, Ohm
|
Zero Adjustment
|
WATT : External adjustment by push button.
|
DCV, ACV, DCA, ACA,: Automatic adjustment
| |
Polarity
|
Automatic switching, "-" indicates reverse polarity
|
Current Input Mode
|
Direct input, inductive clamp probe or CT
|
Over input indication
|
Indication of "------------" or "__________"
|
Data output
|
RS232 serial interface
|
Sampling time
|
W, VA, ACA, ACV, PF, Hz: Approx. 1.5 Sec. DCV, DCA, OHM : Approx. 1 Sec. |
Power supply
|
Battery power : DC 9V , 1.5V AA battery x 6 pcs AC power : AC to DC 9V adapter ( 500 mA ), optional |
Power Consumption
|
Battery power : Approx. DC 50 mA
|
Dimensions
|
280 x 210 x 90 mm ( 11.0 x 8.3 x 3.5 inch )
|
Weight
|
2.4lbs
|
Standard Accessories
|
Test Lead (red & black) 1 pair, Instruction Manual 1 pc.
|
Electrical Specifications:
Watt ( AC, True Power), Current mode from direct input
| ||
Range
|
Resolution
|
Accuracy
|
6,000 Watt
|
0.1 W (< 1000W )
|
+/- ( 1.5% + 5 d ) * Accuracy are specified under the following conditions : a) AC input current is 0.01 ACA & 10 ACA. b) AC input voltage is within 110 V +/- 15 % and 220V +/- 15 %. c) ACA, ACV input signal is sine wave, 50/60 Hz d) Power factor 0.5. * ACA, ACV frequency response is from 40 to 400 Hz. * Max. volt & current input signal value :Volt input : Max. AC 600V, Current input: Max. AC 10 A |
1 W (>=1000W )
| ||
Watt ( AC, true power), current input cooperate with inductive probe or CT
| ||
Range
|
Resolution
|
Accuracy
|
0.1 Watt to 9,999 Watt
|
0.1 Watt
|
* Accuracy will be same as the above " Direct Current Input Mode " but plus the accuracy value of Current Transformer ( CT ) or the accuracy value of Inductive Current Probe.
* Input current should obey: Inductive Probe - 20 ACA. CT 100/5 A - 8 ACA.CT 1000/5 A - 80 ACA.
|
10KW to 99.99 KW
|
0.01 KWatt
| |
100KW to 999.9 KW
|
0.1 KWatt
| |
1000KW to 1999KW
|
1KWatt
| |
VA(AC,Apparent Power) current mode from direct input
| ||
Range
|
Resolution
|
Accuracy
|
0.01 VA to 99.99 VA
|
0.01VA
|
+/- (2% + 2d) * Accuracy are specified under the following conditions : a) AC input current is 0.4 ACA & 10 ACA. b) AC input voltage is within 110 V 15 % and 220V 15%. c) ACA, ACV input signal is sine wave, 50/60 Hz. * ACA, ACV frequency response is from 40 to 400 Hz. |
100.0 VA to 999.9 VA
|
0.1VA
| |
1000 VA to 9999 VA
|
1 VA
| |
10.KVA to 39.99 KVA
|
10VA
| |
Power Factor, current mode from direct input only
| ||
Range
|
Resolution
|
Accuracy
|
0.01 to 1.00
|
0.01
|
+/- (1.5 % + 2d) * Accuracy are specified under the following conditions : a) AC input current is 0.01 ACA & 10 ACA. b) AC input voltage is within 110 V 15 % and 220V 15%. c) ACA, ACV input signal is sine wave, 50/60 Hz. * Max. volt input : AC 600V, Current input : AC 10A |
AC Voltage (true RMS), DC Voltage
| ||
Range
|
Resolution
|
Accuracy
|
0.01V to 299.9 V
|
0.1V
|
DCV : +/- (1% +1d) |
300V to 600 V
|
1V
| |
* Auto range. * Max. input voltage : AC 600 V, DC 600 V. | ||
AC Current (true RMS),DC Current , current mode from direct input (* Max. input current : AC 10 A, DC 10 A)
| ||
Range
|
Resolution
|
Accuracy
|
ACA 0.05A to 1.999 A 2.00A to 10.00 A |
1mA
|
+/- (1% + 3 d )
|
DAC 0.01 A to 10.00 A |
10mA |
+/- (1% + 1 d )
|
AC Current DC Current , current mode from inductive probe
| ||
Range
|
Resolution
|
Accuracy
|
ACA < 2 A |
0.01 A |
* Meter voltage range accuracy plus Inductive Probe's accuracy. |
ACA 2 A to 1000 |
0.1 A |
|
ACA > 1000A
|
1A
|
|
DCA 1000A |
1 A |
|
AC Current , current mode from CT ( current transformer)
| ||
Range
|
Resolution
|
Accuracy
|
CT 100/5A, 0.1 - 200A
|
0.01A, < 20 A 0.1 A, >= 20 A
|
* Meter current range accuracy plus CT (current transformer) accuracy. |
CT 1000/5A, 1 - 2000A
|
0.1 A, , < 20 A 1A, >= 200 A
| |
Watt, Hour, Current from direct input
| ||
Range
|
Resolution
|
Accuracy
|
0.001W hr to 9.999 W hr
|
0.001 W hr
|
* When Watt Hour value over 9999 K W hr, the display value will reset to 0000 K W hr, then count up again. |
10 W hr to 99.99 W hr
|
0.01 W hr
| |
100 W hr to 999.9 W hr
|
0.1 W hr
| |
1000 W hr to 9999 W hr
|
1 W hr
| |
10 kW hr to 99.99 kW hr
|
10 W hr
| |
100 kW hr to 999.9 kW hr
|
100 W hr
| |
1000 kW hr to 9999 kW hr
|
1KW hr
| |
OHMs ( * Auto range. * Overload protection " Max. AC/DC 300 V")
| ||
Range
|
Resolution
|
Accuracy
|
1 Ohm to 9,999 Ohm
|
1 Ohm
|
+/- (1 % + 1 d)
|
10 K Ohm to 19,99K Ohm
|
10 Ohm
| |
Hz ( * Auto range. * Frequency signal input voltage level should > 6V & 600 V) | ||
Range
|
Resolution
|
Accuracy
|
10 Hz to 99.9 Hz
|
0.1 Hz
|
+/- ( 1 % + 1 d)
|
100 Hz to 999 Hz
|
1 Hz
|
?Copyright 2000-2012 Sun Equipment Corporation. Prices and specifications are subject to change without notice