Power Analyzers:| PA-03090A | PA-036090 | PA-036091 |
| Power Analyzer: PA-036090 | $399.95 |
Features:
| * Multi-Functions: Watt, VA, Whr, Power factor, ACV, ACA, DCV, DCA, Hz, Ohm |
| * True AC Power measurement, not apparent power |
| * True RMS display for ACV, ACA |
| * Super large LCD, display WATT, power factor, voltage, current values at the same time |
| * Current mode from direct input, inductive , clamp probe or CT |
| * Auto range |
| * Built-in peak hold & data hold function |
| * Alarm Hi / Low setting capability |
| * RS-232 output interface |
| * Built-in over input indication |
| * Power supply by DC battery or AC to DC adapter |
| * Durable bench type housing plastic |
General specifications:
| Display | 93mm x 52 mm LCD |
| Measurement | WATT, VA, Whr, Power Factor, ACV, ACA, DCV, DCA, Hz, Ohm |
| Zero Adjustment | WATT : External adjustment |
| DCV, ACV, DCA, ACA,: Automatic adjustment | |
| Polarity | Automatic switching, "-" indicates reverse polarity |
| Current Input Mode | Direct input, inductive clamp probe or CT |
| Over input indication | Indication of "------------" or "__________" |
| Data output | RS232 serial interface |
| Sampling time | W, A, V: 1.5 sec; DCV,DCA: 1 sec |
| Power supply | DC 9V , 1.5V AA battery x 6 pcs |
| Power Consumption | Approx. DC 30 mA |
| Dimensions | 11" x 8.3" 3.5" |
| Weight | 2.4lbs |
| Standard Accessories | Test Leads, Instruction Manual |
| Optional Accessories | RS-232 Cable UPCB-02, Software SW-U801-WIN |
Electrical Specifications:
| Watt ( AC, True Power), Current mode from direct input | ||
|
Range |
Resolution |
Accuracy |
|
1 Watt to 9,999 Watt |
1 watt |
+/- (1.5 % + 1d) |
|
10K Watt to 99.99 K Watt |
10 Watt | |
|
Watt ( AC, true power), current from inductive probe or CT | ||
|
Range |
Resolution |
Accuracy |
|
1 Watt to 9,999 Watt |
1 Watt |
+/- (1.5 % + 1d)
|
|
10KW to 99.99 KW |
10 Watt | |
|
100KW to 999.9 kW |
0.1 KWatt | |
|
1000KW to 1999KW |
1KWatt | |
|
VA(AC) current mode from direct input | ||
|
Range |
Resolution |
Accuracy |
|
0.01 VA to 99.99 VA |
0.01VA |
+/- (1.5 % + 1d)
|
|
100.0 VA to 999.9 VA |
0.1VA | |
|
1000 VA to 9999 VA |
1 VA | |
|
10.KVA to 39.99 KVA |
10VA | |
|
Power Factor, current mode from direct input only | ||
|
Range |
Resolution |
Accuracy |
|
0.01 to 1.00 |
0.01 |
+/- (1.5 % + 2d) |
|
AC Voltage, DC Voltage | ||
|
Range |
Resolution |
Accuracy |
|
0.01V to 299.9 V |
0.1V |
+/- (1 % + 1 d )
|
|
300V to 600 V |
1V | |
|
AC Current, DC Current , current mode from direct input | ||
|
Range |
Resolution |
Accuracy |
|
0.01A to 20.00 A |
10mA |
+/- (1% + 1 d ) |
|
AC Current DC Current , current mode from inductive probe | ||
|
Range |
Resolution |
Accuracy |
|
1A to 1000A |
1A |
+/- (1 % + 1 d ) |
|
AC Current , current mode from CT ( current transformer) | ||
|
Range |
Resolution |
Accuracy |
|
CT 100/5A, 0.1 - 100A |
0.1A |
depend on the accuracy of CT
|
|
CT 1000/5A, 1 - 1000A |
1A | |
| Watt, Hour, Current from direct input | ||
|
Range |
Resolution |
Accuracy |
|
0.001W hr to 9.999 W hr |
0.001 W hr |
+/- ( 1% + 1 d) |
|
10 W hr to 99.99 W hr |
0.01 W hr | |
|
100 W hr to 999.9 Whr |
0.1 W hr | |
|
1000 W hr to 9999 W hr |
1 W hr | |
|
10 kW hr to 99.99 kW hr |
10 W hr | |
|
100 kW hr to 999.9 kW hr |
100 W hr | |
|
1000 kW hr to 9999 kW hr |
1KW hr | |
| OHMs | ||
|
Range |
Resolution |
Accuracy |
|
1 Ohm to 9,999 Ohm |
1 Ohm |
+/- (1 % + 1 d) |
|
10 K Ohm to 19,99K Ohm |
10 Ohm | |
| Hz | ||
|
Range |
Resolution |
Accuracy |
|
10 Hz to 99.9 Hz |
0.1 Hz |
+/- ( 1 % + 1 d) |
|
100 Hz to 999 Hz |
1 Hz | |