Power Analyzers: | PA-03090A | PA-036091 |

Power Analyzer: PA-036091 $329.95

Features:

* Multi-Functions: Watt, VA, Whr, Power factor, ACV, ACA, Hz
* True AC Power measurement (Watt), and apparent power (VA)
* True RMS display for ACV, ACA
* Super large LCD, display WATT, power factor, voltage, current values at the same time
* Auto range
* Built-in data hold function
* RS-232 output interface
* Built-in over input indication
* Power supply by DC batteries
* Durable bench type housing plastic

General specifications:

Display 93mm x 52 mm LCD
Measurements WATT, VA, Whr, Power Factor, Hz at the same time
Zero Adjustment WATT : External adjustment
ACV, ACA,: Automatic adjustment
Over input indication Indication of "------------" or "__________"
Data output RS232 serial interface
Sampling time about 1.5 sec
Power supply DC 12V , 1.5V AA battery x 8pcs
Power Consumption Approx. DC 30 mA
Dimensions 6.9" x 5.1"x 3.3"
Weight 1.75 lbs
Standard Accessories Test Leads, Instruction Manual
Optional Accessories RS-232 Cable UPCB-02, Software SW-U801-WIN

Electrical Specifications:

Watt ( AC, True Power), Current mode from direct input
Range
Resolution
Accuracy
6000 Watts
1 watt
+/- (1.5 % + 1d)
10K Watt to 99.99 K Watt
10 Watt
Watt ( AC, true power), current from inductive probe or CT
Range
Resolution
Accuracy
1 Watt to 9,999 Watt
1 Watt
+/- (1.5 % + 1d)
10KW to 99.99 KW
0.01 KW
100KW to 999.9 kW
0.1 KW
   
VA(AC) current mode from direct input
Range
Resolution
Accuracy
0.01 VA to 99.99 VA
0.01VA
+/- (1.5 % + 1d)
100.0 VA to 999.9 VA
0.1VA
1000 VA to 6000VA
1 VA
   
Power Factor, current mode from direct input only
Range
Resolution
Accuracy
0.01 to 1.00
0.01
+/- (1.5 % + 2d)
AC Voltage (True RMS)
Range
Resolution
Accuracy
0.1V to 299.9 V
0.1V
+/- (1 % + 1 d )
300V to 600 V
1V
AC Current (True RMS), current mode from direct input
Range
Resolution
Accuracy
0.01A to 10.00 A
10mA
+/- (1% + 1 d )
AC Current , current mode from CT ( current transformer)
Range
Resolution
Accuracy
CT 100/5A, 0.1 - 200A
0.1A
depend on the accuracy of CT
CT 1000/5A, 1 - 2000A
1A
Watt, Hour, Current from direct input
Range
Resolution
Accuracy
0.001W hr to 9.999 W hr
0.001 W hr
+/- ( 1% + 1 d)
10 W hr to 99.99 W hr
0.01 W hr
100 W hr to 999.9 Whr
0.1 W hr
1000 W hr to 9999 W hr
1 W hr
10 kW hr to 99.99 kW hr
10 W hr
100 kW hr to 999.9 kW hr
100 W hr
1000 kW hr to 9999 kW hr
1KW hr
Hz
Range
Resolution
Accuracy
10 Hz to 99.9 Hz
0.1 Hz
+/- ( 1 % + 1 d)
100 Hz to 999 Hz
1 Hz

 

 

© Copyright 1995~2009 Sun Equipment Corporation. All rights reserved Prices and specs are subject to change without notice.